Ectane 2

Over the last decade, Eddyfi Ectane® has become the undisputed reference for heat exchanger tubing inspection and surface eddy current array, all around the globe. Thanks to a compact form-factor and its unmatched robustness, the multi-technology instrument earned a reputation for being best-in-class.

Tecnologías

  • Prueba de Corrientes de Eddy (ECT)
  • Arreglo de Corrientes de Eddy (ECA)
  • Arreglo de Corrientes de Eddy Tangenciales (TECA)
  • Prueba de Campo Remoto (RFT)
  • Prueba de Campo Cercano (NFT)
  • Arreglo de Campo Cercano (NFA)
  • Fuga de Flujo Magnético (MFL)
  • Prueba ultrasónica del sistema de inspección giratorio interno (IRIS)

Versatilidad tecnológica incorporada

Las pruebas no destructivas de tubos y superficies se basan en una serie de técnicas, que a menudo dependen de la aplicación y los materiales involucrados. Usó las capacidades integradas de Ectane 2 con casi cualquier combinación de las tecnologías de prueba enumeradas.

Cualquiera que sea la tecnología, Ectane 2 puede manejarlo sin cajas externas o conexiones torpes.

Ectane 2 también puede activar sondas ECT de saturación parcial y sondas ECT de polarización magnética con su fuente de corriente integrada y sondas RPC con su motor.

Benefits

Applications

  • All technologies required in a single instrument.
  • Portable and compact
  • Robust and shock-resistant
  • Sealed and water-resistant
  • Battery-powered
  • Seamlessly integrated with Probot
  • Works with industry-leading software
  • Heat exchangers (ferrous and non-ferrous)
  • Condensers, Feedwater heaters
  • Fin-fan air coolers and boilers
  • Chillers, air conditioning / HVAC
  • Balance of Plant
  • Surface ECA inspection for nuclear components
  • In-line / quality control surface ECA inspections

Portability and Autonomy

The Eddyfi Ectane 2 test instrument is approximately 10 L (610 cu.in.) in volume and weighs in at 6.8 kg (15 lb), making it about three times more compact than other legacy test instruments. Ectane 2 is therefore easy to carry beyond being rugged. The instrument is also battery powered with 8 hours of autonomy that eliminate the need for an external power source.

Unlike some fragile systems on the market, Ectane was built for real-life conditions: cold, hot, dusty, humid (or simply wet!), where occasional shocks and drops are meant to happen. Ectane is the tester you can trust.

Features

Powerful CPU Board — The Ectane 2’s board (100% Eddyfi) has a faster CPU, which delivers more punch for ultrafast probe nulling and real-time processing. This greatly contributes to making quality inspections with the Ectane 2 easier than ever before with any technology combination, whether it is ECT, ECA, TECA, RFT, NFT, NFA, MFL, or IRIS.

Improved Maximum Frequency — The maximum ECT frequency is now 10 MHz, which offers more flexibility and better performance in a variety of tubing and surface applications.

Current Source for Saturation Probes — Available on the 41-pin connector, this built-in source can be programmed to control the current output that feeds into partial saturation ECT probes and magnetic bias ECT probes.

Motor Drive for RPC Probes — The Ectane 2 is capable of driving motorized rotating pancake coil (RPC) probes, thanks to its powerful built-in motor drive. This is useful in applications where RPC probes are used to find longitudinal and circumferential cracks.

Specifications

GENERAL

Dimensions (W × D × H) 279.6 × 254.0 × 158.8 mm (11.00 × 10.00 × 6.25 in)

Weight: With batteries: 6.8 kg (15 lb)

Without batteries: 5.9 kg (13 lb)

Volume 10 L (610 in3)

Battery autonomy (typical) 8 hours

Cooling Sealed and fanless

Compliance: ASME, EN 61010-1, CE, WEEE, FCC Part 15B, ICES-003, AS/NZS CISPR 22, RoHS

ECT

Probe inputs: 8

Frequencies: Up to 160

Frequency range: 5 Hz–10 MHz

Generator output/coil drive: Up to 20 Vpp

ECA

Number of channels: 64, 128, or 256

RFT AND NFT

Probe inputs: 4

EXTENDED ET

connector: 8

Frequencies: 5

NFA

Number of channels: 64

MFL

Probe inputs: 4

EXTENDED ET connector: 8

IRIS

Internal pulser/receiver

0–200 V drive

0–70 dB (1 dB steps)

0–40 dB DAC

Transducer frequency: 5–20 MHz

Maximum pulsing rate: Up to 26 kHz

Views

Real-time A, B, and C-scans

Wall thickness measurements

50% thinner than competitors (patent pending)

Turbine speed: Up to 100 RPS for fast pulling